Product was successfully added to your shopping cart.
  • Twelve Panel Clear Scan Drug Test Cup W/ Adulterants Twelve Panel Clear Scan Drug Test Cup W/ Adulterants
  • Twelve Panel Clear Scan Drug Test Cup W/ Adulterants  image 2 Twelve Panel Clear Scan Drug Test Cup W/ Adulterants  thumbnail 2
  • Twelve Panel Clear Scan Drug Test Cup W/ Adulterants  image 3 Twelve Panel Clear Scan Drug Test Cup W/ Adulterants  thumbnail 3
Scroll to Cart

Twelve Panel Clear Scan Drug Test Cup W/ Adulterants

Be the first to review this product

Quick Overview

  • Flat Front for Photocopying
  • Quick Results
  • Up to 99% Accuracy
  • No Leak Design
  • Up to 12 Drugs
  • Easy to Read Results

Availability: In stock

Product sold in cases (25 tests per case)
1-34-1112-1920-3940+
$156.25$143.75$137.50$131.50$122.50
$6.25 each$5.75 each$5.50 each$5.26 each$4.90 each
* Discounts may vary based on options above
ModelDrugs Tested
CSC-6125ADAMP / BAR / BUP / BZO / COC / mAMP / MDMA / MTD / MOP / OXY / PCP / THC + OX / PH / SG

Additional Information

This flat front design 12 panel Clear Scan drug test cup is a product that is made for professional use. The flat front design makes photocopying resuls a breeze and allows for accurate record keepings. This cup is CLIA Waived and FDA Approved, which means it adheres to the highest standards of accuracy and quality. In addition to testing for 12 substances in one test, this device also tests for adulteration so it detects signs of tampering.

 

Per Case25
Panel Count12
With AdulterantsYes
AdulterantsOxidants, pH Balance, Specific Gravity
ControlsNC-1, PC-1
Application Typeurine cup
CLIA Waived?Yes
FDA ClearedYes
Forensic only?No
DOT Approved?No
Avg Competitor Price$187.50

Details


PERFORMING THE TEST


Before testing:

Read the instructions completely.
Check the expiration date on the box. Do not use the test if it is expired. Have a watch, clock or timer ready.

Step 1: Tear the foil bag open, remove the test cup and disposable glove pack provided for donor. Label the device with donor information. (Fig. 1)

Step 2: Open test cup lid. Urinate directly into the test cup. Be sure to fill the test cup with the urine specimen provided between a minimum of 30ml to maximum 110ml (marked on the cup). (Fig. 2)

Step 3: After urine specimen has been collected, close the lid securely and return cup to collection official. (Fig. 3)

Step 4: Collection official should use the gloves provided. Peel off the label to reveal test result. Read the test result at 5 minutes.

DO NOT INTERPRET RESULT AFTER 10 MINUTES. (Fig. 4&5) 

INTERPRETATION OF RESULTS


Negative Result

NEGATIVE: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T). Certain lines may appear lighter or thinner than other lines. A line is to be considered a line whether it is faint, light or dark.

*NOTE: The shade of red in the test line region (Drug/T) will vary, but it should be considered negative whenever there is even a faint pink line.

Preliminary Positive Result:

POSITIVE: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).

Invalid Result:

INVALID: Control band fails to appear. Results from any test which has not produced a control band at the specific read time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.


STORAGE AND STABILITY


Store as packaged in the sealed pouch at room temperature. The test device is stable through the expiration date printed on the sealed pouch.

The test device must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date.

Details

ADULTERATION TEST

Urine sample adulteration is usually achieved by substitution, dilution or the addition of adulterants including so-called "masking agents" sold commercially. The use of adulterants can cause false negative results in drug tests by either interfering with the test and/or destroying drugs present in the urine. Dilution may also be used in an attempt to produce false negative drug test results.

The Drug Tests In Bulk PreScreen Plus Test (CLIA Waived) adulteration test is based on the color response of chemical indicators in the presence of adulterants. pH (P), specific gravity (S), oxidant/PCC (O), creatinine (C), nitrite (N) and glutaraldehyde (G) are tested to determine the integrity of urine samples.

pH: The pH determination of urine samples is based on the color change of an indicator in an acidic or basic medium. Normal urine pH ranges from 4 to 9. Values outside of this range may indicate the sample has been altered.

Specific Gravity: The specific gravity test is based on the pKa change of certain pretreated polyelectrolytes in relation to the ionic concentration. In the presence of an indicator, the colors change from dark blue to blue-green in urine of low ionic concentration to green and yellow- green in urine of higher ionic concentration. The normal range for specific gravity is from 1.003 to 1.030. Values outside this range generally indicate specimen dilution or adulteration.

Oxidants/PCC (Pyridinium Chlorochromate): Bleach, hydrogen peroxide, pyridinium chlorochromate or other oxidizing agents react with an oxidant indicator to form a color complex. A blue-green, brown, or orange color indicates adulteration with bleach or other oxidizing agents. Normal human urine should not contain oxidants.

Creatinine: Creatinine reacts with an indicator in an alkaline medium to form a purplish-brown color complex. The normal range of creatinine is from 20 to 300 mg/dl. Values outside this range generally indicate a manipulated test.

Nitrite: Nitrite reacts with the reagents aromatic amine to form a diazonium salt which couples with an indicator to yield a pink-red/purple color complex. A urine sample containing nitrite at a level greater than 15 mg/dl is considered adulterated.

Glutaraldehyde: Adulterants such as "Clear Choice" contain glutaraldehyde which may cause disrupting the enzyme used in some immunoassay tests. Glutaraldehyde is not normally found in human urine.

Details

ModelDrugs Tested:
CSC-6125ADAMP1000, BAR300, BUP10, BZO300, COC300, mAMP1000, MDMA500, MTD300, MOP300, OXY100, PCP25, THC50
Drug NameABBCutoff LevelApprox Detection
time in Urine
Approximate Detection
time in Saliva
AmphetamineAMP500 ng/ml2-4 Days1-3 Days
1000 ng/ml2-4 DaysN/A
BarbituratesBAR300 ng/ml3-6 Days1 Day
BenzodiazepinesBZO300 ng/ml3-7 Days1-2 Days
BuprenorphineBUP10 ng/ml2-3 Days1 Day
CocaineCOC150 ng/ml2-4 DaysN/A
300 ng/ml2-4 Days1-3 Days
EcstasyMDMA500 ng/ml1-3 Days1-2 Days
FentanylFEN300 ng/ml3 DaysN/A
K2 / SpiceK2/Spice50 ng/ml1-3 DaysN/A
MarijuanaTHC50 ng/ml5-30 Days1 Day
20 ng/MLUp To 30 daysN/A
MethadoneMTD50 ng/ml3-5 Days1 Day
MethamphetamineMAMP1000 ng/ml3-5 Days1-3 Days
500 ng/ml3-5 DaysN/A
MorphineMOP300 ng/ml2-4 Days1-3 Days
OpiatesOPI2000 ng/ml2-4 Days1-3 Days
OxycodoneOXY100 ng/ml2-4 Days1 Day
PhencyclidinePCP25 ng/ml5-10 Days1-3 Days
Tricyclic AntidepressantsTCA1000 ng/ml3-6 DaysN/A
PropoxyphenePPX300 ng/ml1-2 DaysN/A
*Detection times should be considered estimates.

Downloadable Product Inserts:

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

 1 star2 stars3 stars4 stars5 stars
Quality
Value
Price
4x Buyer Protection Image