Product was successfully added to your shopping cart.
  • 10 Panel Drug Screen Cup IV Drug Test 10 Panel Drug Screen Cup IV Drug Test
  • 10 Panel Drug Screen Cup IV Drug Test image 2 10 Panel Drug Screen Cup IV Drug Test thumbnail 2
Scroll to Cart
Previous

5 Panel Drug Screen Cup IV Drug Test

Previous

12 Panel Drug Screen Cup IV Drug Test

10 Panel Drug Screen Cup IV Drug Test

Be the first to review this product

Quick Overview

  • Up to 10 Drugs
  • CLIA Waived
  • Results in 5 Minutes
  • Easy to Read Results

Availability: In stock

Product sold in cases (25 tests per case)
1-34-1112-1920-3940+
$118.00$114.25$109.25$106.25$101.25
$4.72 each$4.57 each$4.37 each$4.25 each$4.05 each
* Discounts may vary based on options above
ModelDrugs Tested
D708085AMP / BAR / BZO / COC / MET / MTD / OPI / OXY / PCP / THC

Additional Information

The 10 Panel Drug Screen Cup IV Drug Test (CLIA Waived) is a great choice for performing the initial testing. The urine test cup can detect up to 10 different illicit drugs in one testing.

 

Per Case25
Panel Count10
With AdulterantsNo
AdulterantsNo
ControlsNC-1, PC-1
Application Typeurine cup
CLIA Waived?Yes
FDA ClearedYes
Forensic only?No
DOT Approved?No
Avg Competitor Price$142.00

Details


PERFORMING THE TEST


Before testing:

Bring tests, specimens ,and/or controls to room temperature (15-30°C) before use if stored at refrigerated temperatures. Remove the cup from sealed pouch and use it as soon as possible.

Step 1: Donor dates and initials body label.

Step 2: Donor provides a urine specimen in the cup and screws cap on to it. Start timer immediately. 

Step 3: Operator checks the cap for tightness.

Step 4: Remove the peel-off label.

Step 5: Check the temperature strip label at 2-4 minutes after specimen collection for the fresh urine specimen. A green color will appear to indicate the temperature of the urine specimen. The proper range for an unadulterated specimen is 90-100°F (32-38°C).

Step 6: Drug test results are indicated by the presence or absence of colored band(s) in the result area of the test strips. The result should be read at 5 minutes. Do not interpret the result after 10 minutes. 

Step 7: Positive test results must be confirmed by another test method. Send the cup and urine specimen intact to a toxicology laboratory for confirmation.

Step 8: For the adulteration, compared with the color card, and the results should be read at 2 minutes,do not interpret the result after 5 minutes.

Step 9: For alcohol test, read results at 2 minutes by visually comparing the color of the reaction pad to the corresponding color blocks printed on the pouch to determine the alcohol concentration. Do not interpret the result after 3 minutes. For the adulteration, compared with the color card and the results should be read at 2 minutes, do not interpret the result after 5 minutes. 


INTERPRETATION OF RESULTS


Negative Result

NEGATIVE: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T). Certain lines may appear lighter or thinner than other lines. A line is to be considered a line whether it is faint, light or dark.

*NOTE: The shade of red in the test line region (Drug/T) will vary, but it should be considered negative whenever there is even a faint pink line.

Preliminary Positive Result:

POSITIVE: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).

Invalid Result:

INVALID: Control band fails to appear. Results from any test which has not produced a control band at the specific read time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.


STORAGE AND STABILITY


  • The kit should be stored at 2-30°C until the expiry date printed on the sealed pouch.
  • The test must remain in the sealed pouch until use.
  • Do not freeze.
  • Kits should be kept out of direct sunlight.
  • Care should be taken to protect the components of the kit from contamination. Do not use if there is evidence of microbial contamination or precipitation. Biological contamination of dispensing equipment, containers or reagents can lead to false results.

Details

ModelDrugs Tested:
D708085AMP1000, BAR300, BZO300, COC300, MET1000, MTD300, OPI2000, OXY100, PCP25, THC50
Drug NameABBCutoff LevelApprox Detection
time in Urine
Approximate Detection
time in Saliva
AmphetamineAMP500 ng/ml2-4 Days1-3 Days
1000 ng/ml2-4 DaysN/A
BarbituratesBAR300 ng/ml3-6 Days1 Day
BenzodiazepinesBZO300 ng/ml3-7 Days1-2 Days
BuprenorphineBUP10 ng/ml2-3 Days1 Day
CocaineCOC150 ng/ml2-4 DaysN/A
300 ng/ml2-4 Days1-3 Days
EcstasyMDMA500 ng/ml1-3 Days1-2 Days
FentanylFEN300 ng/ml3 DaysN/A
K2 / SpiceK2/Spice50 ng/ml1-3 DaysN/A
MarijuanaTHC50 ng/ml5-30 Days1 Day
20 ng/MLUp To 30 daysN/A
MethadoneMTD50 ng/ml3-5 Days1 Day
MethamphetamineMAMP1000 ng/ml3-5 Days1-3 Days
500 ng/ml3-5 DaysN/A
MorphineMOP300 ng/ml2-4 Days1-3 Days
OpiatesOPI2000 ng/ml2-4 Days1-3 Days
OxycodoneOXY100 ng/ml2-4 Days1 Day
PhencyclidinePCP25 ng/ml5-10 Days1-3 Days
Tricyclic AntidepressantsTCA1000 ng/ml3-6 DaysN/A
PropoxyphenePPX300 ng/ml1-2 DaysN/A
*Detection times should be considered estimates.

Downloadable Product Inserts:

  1. Be the first to review this product

Write Your Own Review

How do you rate this product? *

 1 star2 stars3 stars4 stars5 stars
Quality
Value
Price
4x Buyer Protection Image