Twelve Panel Clear Scan Drug Test Cup With Adulterants (CLIA Waived)

Twelve Panel Clear Scan Drug Test Cup With Adulterants (CLIA Waived)

Five Panel PreScreen Plus Cup With Adulterants (CLIA Waived)

Five Panel PreScreen Plus Cup With Adulterants (CLIA Waived)

NICDetect Oral Cotinine Test

  • 30 ng/mL cutoff
  • Results in Under 10 Minutes
  • Accurately Detect Cotinine (Metabolite of Nicotine)
  • 510K Exempt for Determination ONLY
  • Every Case Includes 3 Additional Collection Devices

Availability: In stock

Buy more, save more!

only $130.00 when you buy 4 cases or more.

Product sold in cases of 25 tests
1-34+
$137.50$130.00
$5.50 each$5.20 each
*Discounts may vary based on options above
Model Drugs Tested
ICO-NIC COT
  • Buy 4 for $130.00 each and save 5%

You've just added this product to the cart:

NICDetect Oral Cotinine Test

The NicDetect is an oral fluid cotinine rapid test that offers exceptional accuracy and provides results in less than 10 minutes. The NicDetect with its 30 ng/mL cutoff, targets routine, daily, and habitual tobacco/nicotine users and eliminates light-use smokers, tobacco, nicotine users, e.g., occasional cigar smokers. This oral swab type test allows you to collect anytime/anywhere, is easy to use and read, and provides instant results instead of waiting 24-48 hours on a laboratory send out

Examples of potential Nic Detect Users:

Life Insurance Industry
• Risk stratification – issuing policy and pricing

Occupational Health/Wellness/Workplace testing for employees
• Pre-employment – Promote a nicotine free workplace
• Risk stratification – Benefits pricing determination/Premium Differential

Cessation Programs

Communities
• Schools – activities
• Concerned parents
More Information
All Sales Final No
Tagline Results Interpretation
Avg Competitor Price $187.50
Per Case 25
Panel Count 1
With Adulterants No
Controls N/A
Application Type saliva
CLIA Waived? No
FDA Cleared No
For Employment and Insurance Use No
Forensic only? N/A
DOT Approved? No

DIRECTIONS FOR USE


Instruct the donor to not place anything in the mouth including food, drink, gum, and tobacco products for at least 10 minutes prior to collection.

Step 1: Remove the test device from the pouch and use it as soon as quickly as possible.

Step 2: Remove the collector from the sealed pouch. Take out of the collector cap; Insert the sponge into the mouth. Close mouth and move the sponge around for oral fluid collection. Soak sponge in oral fluid and swab the inside of the mouth and tongue. Collect oral fluid for 3 minutes OR until sponge is soft and fully saturated, No hard spots should be felt on the sponge when saturated.

Step 3: Place the test device on a clean and level surface. Remove the collection sponge from the mouth and insert the sponge GENTLY into the screening device, push down until the collector cap sealed with the device tightly. (See illustration 2)

Step 4: Leave test device upright on flat surface and keep upright while test is running. Wait for the colored lines to appear in test results area. Read the results at 10 minutes. Do not interpret results after 15 minutes

Note: Once the collection sponge locks in place, the device is airtight, tamper evident, and ready to be disposed or sent to lab for confirmation (on presumptive positive results)


INTERPRETATION OF RESULTS


Negative Result

NEGATIVE: Two colored bands appear on the membrane. One band appears in the control region (C) and another band appears in the test region (T). Certain lines may appear lighter or thinner than other lines. A line is to be considered a line whether it is faint, light or dark.

*NOTE: The shade of red in the test line region (Drug/T) will vary, but it should be considered negative whenever there is even a faint pink line.

Preliminary Positive Result:

POSITIVE: Only one colored band appears, in the control region (C). No apparent colored band appears in the test region (T).

Invalid Result:

INVALID: Control band fails to appear. Results from any test which has not produced a control band at the specific read time must be discarded. Please review the procedure and repeat with a new test. If the problem persists, discontinue using the kit immediately and contact your local distributor.

  1. The InstaCube Oral Drug Test provides only a qualitative, preliminary analytical result. A secondary analytical method must be used to obtain a confirmed result. Gas chromatography/mass spectrometry (GC/MS) or gas chromatography/tandem mass spectrometry (GC/MS/MS) is the preferred confirmatory method.
  2. There is a possibility that technical or procedural errors, as well as other interfering substances in the oral fluid specimen may cause erroneous results.
  3. A positive test result does not indicate the concentration of drug in the specimen or the route of administration.

STORAGE AND STABILITY


Store as packaged in the sealed pouch at room temperature. The test device is stable through the expiration date printed on the sealed pouch.

The test device must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date.

Model Drugs Tested:
ICO-NIC COT30
Drug NameABBRCalibratorStandard Cutoff Levels UrineStandard Cutoff Levels SalivaApprox. Detection Time UrineApprox. Detection Time Saliva
Alcohol

ALC

Ethanol

>0.04%

>0.02%

1-12 hours

1-12 hours

**

AMP

**

500 & 1000 ng/ml

50 ng/ml

2-4 Days

1-3 Days

Barbiturates

BAR

Secobartbital

300 ng/ml

50 ng/ml

1-3 Days

1 Day

Benzodiazepines

BZO

Oxazepam

300 ng/ml

10 ng/ml

3-5 Days

1 Day

Buprenorphine

BUP

Buprenorphine

10 ng/ml

5 ng/ml

3-5 Days

1 Day

Cocaine

COC

Benzoylecgonine

150 & 300 ng/ml

20 ng/ml

2-4 Days (Single)
> 2 Weeks (Long Term)

1-3 Days

Cotinine

COT

Cotinine

200 ng/ml

30 ng/ml

1-3 Days

1-4 Days

Ecstasy

MDMA

D,L- Methylenedioxy-methamphetamine

500 ng/ml

NA

1-4 Days

1-2 Days

Ethyl Glucuronide 

ETG

Ethyl Glucuronide

300 & 500 ng/ml

NA

Up to 80 Hours

N/A

**

FEN

**

200 & 300 ng/ml

10 ng/ml

3 Days

N/A

Gabapentin

GABA

Gabapentin

1000 ng/ml

N/A

1-2 Days

N/A

K2 / Spice

K2/Spice

JWH-073/JWH-018

50 ng/ml

5 ng/ml

1-3 Days

N/A

Ketamine

KET

Ketamine

1000 ng/ml

N/A

1-3 Days

1 Day

Marijuana

THC

11-nor-Δ9-THC-9 COOH

50 ng/ml

12 ng/ml

2-5 Days (Single)
14-21 days (Long Term)

Results vary from 1 hour to 1 Day.  Per SAMHSA,THC test results are more limited in all oral fluid testing. See related blog.

Methadone

MTD

Methadone

50 ng/ml

30 ng/ml

1-7 days

1 Day

Methamphetamine

MAMP

D-Methamphetamine

500 & 1000 ng/ml

50 ng/ml

2-4  Days

1-3 Days

Morphine

MOP

Morphine

300 ng/ml

40 ng/ml

1-3 Days

1-3 Days

Opiates

OPI

Morphine

2000 ng/ml

Oxycodone

OXY

Oxycodone

100 ng/ml

20 ng/ml

1-3 Days

1 Day

Phencyclidine

PCP

Phencyclidine

25 ng/ml

10 ng/ml

2-13 Days

1-3 Days

**

TRA

**

200 ng/ml

NA

1-3 Days

1 Day

Tricyclic Antidepressants

TCA

Nortriptyline

1000 ng/ml

NA

2-5 Days

N/A

Propoxyphene

PPX

Propoxyphene

300 ng/ml

NA

1-7 Days

N/A

*The above chart gives approximate detection periods for each substance by test type. The ranges depend on amount and frequency of use, metabolic rate, body mass, age, overall health, drug tolerance, urine pH, and other additional factors